Version 1.9.2-taction15a

Updates:

  • Fixed tracker XML output when there are network problems
  • Fixed time-tag missing from TUIO bundles
  • Fixed damaged frames being shown on OSD
  • Fixed firmware update on Windows requiring user to click through the wizard
  • Changed default parameters for image merging on UTB models
  • Released 9.1.2014

Known issues:

  • Pen tracker cannot be used with the hybrid tracking
  • Slow clicking (=press and hold) a button in OSD does work even if it visually appears so. Workaround is to click fast.
  • Automatic USB drive mounting doesn't work on Linux models

Version 1.9.2-taction15

Updates:

  • Fixed an issue with OSD restarting every 1-2 hours when the device is in stand-by mode
  • Fixed a regression issue where large square markers could report incorrect codes
  • Added marker velocity and acceleration to TUIO output
  • Fixed correct units for velocity and invalid value for acceleration in TUIO finger output
  • Released 17.10.2013

Known issues:

  • Pen tracker cannot be used with the hybrid tracking
  • Slow clicking (=press and hold) a button in OSD does work even if it visually appears so. Workaround is to click fast.
  • Automatic USB drive mounting doesn't work on Linux models

Version 1.9.2-taction14f

Updates:

  • Added an option to change background removal mode
  • Released 13.9.2013

Known issues:

  • Pen tracker cannot be used with the hybrid tracking
  • Slow clicking (=press and hold) a button in OSD does work even if it visually appears so. Workaround is to click fast.
  • Automatic USB drive mounting doesn't work on Linux models

Version 1.9.2-taction14d

Updates:

  • Tracker background calibration now works correctly if hybrid tracking is enabled
  • Released 3.9.2013

Known issues:

  • Pen tracker cannot be used with the hybrid tracking
  • Slow clicking (=press and hold) a button in OSD does work even if it visually appears so. Workaround is to click fast.
  • Automatic USB drive mounting doesn't work on Linux models

Version 1.9.2-taction14c

Updates:

  • New MultiTaction Setup utility in Windows Cells
  • Fixed crash on stand-by mode when having Cornerstone 2.0 clients connected
  • More robust Windows tracker service launching
  • Released 26.8.2013

Known issues:

  • Pen tracker cannot be used with the hybrid tracking
  • Slow clicking (=press and hold) a button in OSD does work even if it visually appears so. Workaround is to click fast.
  • Automatic USB drive mounting doesn't work on Linux models

Version 1.9.2-taction14b

Updates:

  • Fixed color-correction with SiteManager
  • Fixed auto-calibration state query with SiteManager
  • Released 31.7.2013

Known issues:

  • Pen tracker cannot be used with the hybrid tracking
  • Slow clicking (=press and hold) a button in OSD does work even if it visually appears so. Workaround is to click fast.
  • Automatic USB drive mounting doesn't work on Linux models

Version 1.9.2-taction14a

Updates:

  • Increased watchdog check intervals, fixes occasional crash on stackable models during geometry calibration
  • Released 12.7.2013

Known issues:

  • Pen tracker cannot be used with the hybrid tracking
  • Slow clicking (=press and hold) a button in OSD does work even if it visually appears so. Workaround is to click fast.
  • Automatic USB drive mounting doesn't work on Linux models

Version 1.9.2-taction14

Updates:

  • Increased temperature limits
  • Fixes to temperature monitoring
  • Fixed an issue where OSD sometimes hangs on exit and sometimes makes the unit nonresponsive
  • Improved marker tracking
  • Improved geometry calibration
  • Released 12.7.2013

Known issues:

  • Pen tracker cannot be used with the hybrid tracking
  • Slow clicking (=press and hold) a button in OSD does work even if it visually appears so. Workaround is to click fast.
  • Automatic USB drive mounting doesn't work on Linux models

Version 1.9.2-taction13b

Updates:

  • Increased VM1 temperature limits
  • Released 18.6.2013 (W7, W8 and L models), 19.6.2013 (S models)

Known issues:

  • Pen tracker cannot be used with the hybrid tracking
  • Slow clicking (=press and hold) a button in OSD does work even if it visually appears so. Workaround is to click fast.

Version 1.9.2-taction13a

Updates:

  • Fixed a regression in auto-calibration
  • Released 5.6.2013

Known issues:

  • Pen tracker cannot be used with the hybrid tracking
  • Slow clicking (=press and hold) a button in OSD does work even if it visually appears so. Workaround is to click fast.

Version 1.9.2-taction12

Updates:

  • Added AMX support for Windows models
  • Added keep-alive parameter for fingers
  • Added overheat protection to prevent hardware damage
  • Fixed AMX server pinging
  • Improved tracker service startup on Windows models
  • Added VM1 support to Windows models
  • Released 5.6.2013

Known issues:

  • Pen tracker cannot be used with the hybrid tracking
  • Slow clicking (=press and hold) a button in OSD does work even if it visually appears so. Workaround is to click fast.

Version 1.9.2-taction11

Updates:

  • Fixed update issue with L models
  • Released 22.5.2013

Known issues:

  • Pen tracker cannot be used with the hybrid tracking
  • Slow clicking (=press and hold) a button in OSD does work even if it visually appears so. Workaround is to click fast.

Version 1.9.2-taction10

Updates:

  • Support for updating existing devices to use CUDA tracker
  • More robust geometry calibration, especially in Windows
  • Added limited AMX/SiteManager support for embedded Linux without starting OSD
  • Removed conflicts between CornerStone 1.2 and tracker files in Windows
  • Color-calibration can be toggled on/off in OSD to compare before/after results
  • Increased maximum keep alive-value for square markers to 100
  • Miscellaneous bug fixes
  • Released 13.5.2013

Known issues:

  • Pen tracker cannot be used with the hybrid tracking
  • Slow clicking (=press and hold) a button in OSD does work even if it visually appears so. Workaround is to click fast.

Version 1.9.2-taction7a

NOTE: this version is not available for embedded models (W7/W8/L)

Updates:

  • AMX 1.1.0 support
  • Fixed ghost markers sometimes being left on screen
  • Temperature monitoring
  • Released 28.02.2013

Known issues:

  • Pen tracker cannot be used with the hybrid tracking
  • Slow clicking (=press and hold) a button in OSD does work even if it visually appears so. Workaround is to click fast.

Version 1.9.2-taction7

Updates:

  • Fixed a marker burn-in issue
  • Enhanced background calibration
  • Hybrid tracking has been improved in situations where there is little ambient infrared light
  • Available for for all MultiTaction devices via the on-line update
  • Released 18.12.2012

Known issues:

  • Pen tracker cannot be used with the hybrid tracking
  • Slow clicking (=press and hold) a button in OSD does work even if it visually appears so. Workaround is to click fast.
  • Update does not work in embedded windows models W7/W8

Version 1.9.2-taction6

Updates:

  • Fixed a regression bug affecting some MT553UTB models
  • Available for MT420S, MT550, MT550S and MT553
  • Released 28.11.2012

Known issues:

  • Pen tracker cannot be used with the hybrid tracking

Version 1.9.2-taction4

Updates:

  • Bug fixes to the geometry calibration
  • Available for MT420S, MT550, MT550S and MT553
  • Released 23.11.2012

Known issues:

  • Pen tracker cannot be used with the hybrid tracking

Version 1.9.2-taction3

Updates:

  • Beta-support for hybrid tracking
  • Fixes for the "black camera" -problem
  • Available for MT420S, MT550, MT550S and MT553
  • Released 12.11.2012

Known issues:

  • Pen tracker cannot be used with the hybrid tracking
  • After geometry calibration the screen is unresponsive for 30 seconds

Version 1.9.2-taction1

Updates:

  • New color-correction curves, for more flexible color correction

Version 1.9.1-taction16

  • Improved finger and marker tracking
  • Support for circle markers
  • Released 30.7.2012

Version 1.9.1-taction15

  • A release for MT550W7, functionally equal to taction13
  • Released 18.7.2012

Version 1.9.1-taction13

  • IR Pen Support
  • Updated TUIO sender
  • PenMarker -> SquareMarker conversion for Cornerstone 1.2 clients
  • OSD: Enable/Disable CV extensions
  • OSD: Added separate "External Source" and "Quit" -buttons
  • Windows: Improved switching between external and internal input
  • Windows: Added BinaryData/XML stream exceptions to Windows firewall
  • Windows: Close the tracker service if tracker is run manually in a standalone application
  • Windows: Fixed an issue where configuration could be saved to wrong directory
  • Tracker: Fixed marker location fractional part truncation
  • Tracker: Use unique ids in all marker trackers
  • Released 29.6.2012

Version 1.9.1-taction12

  • OSD Shows download progress
  • The tracking configuration files are now forward-compatible (easier roll-back if necessary)
  • Released 16.5.2012

Version 1.9.1-taction11

  • Better recovery from internal errors without restarting the tracker
  • Fixed crash on shutdown
  • Released 2.5.2012

Version 1.9.1-taction10

  • Fixed issue when tracking could freeze with older firmware
  • Released 19.4.2012

Version 1.9.1-taction9

  • Support MT420 and MT550W7
  • Updated all presets and default values
  • Fixed OSD timeout and internal/external display selection
  • Support for new DGU with different IP address
  • Do not allow to use conflicting IP network with external network (aka "192.168.0.0/24-problem")
  • Fixed some rare cases when network settings didn't apply properly
  • Better finger orientation detection
  • Fixed a bug where markers had wrong rotation when moving
  • A number of other computer vision improvements
  • TUIO fixes
  • Released 12.4.2012

Version 1.9.1-taction8

  • Support for MT420
  • Fixed marker rotation if filtering is used
  • Autocalibration improved
  • Finger tracking improved
  • Released 4.4.2011

Version 1.9.1-taction7

  • Bug fixes for MultiTaction devices with Embedded Windows (MT550W7)
  • Released 14.3.2012

Version 1.9.1-taction6

  • Virtual keyboard fixes, including a numberic keyboard for IP addresses
  • Optimized style changes, OSD is much faster now
  • OSD: IP settings are read-only in DHCP mode
  • OSD: Show VM1 version and state information in about-widget
  • OSD: Slider improvements
  • OSD: Show MAC address in about-screen
  • OSD/MultiTaction: HTTP Proxy support/UI
  • Handle damaged frames better in CV
  • Released 15.2.2012

Version 1.9.1-taction5

  • Simple tracking visualization
  • Input-transform fixes
  • Advanced-mode with extra sliders
  • Released 20.1.2012

Version 1.9.1-taction4

  • Bug fixes
  • Presets
  • New input handling
  • Released 16.1.2012

Version 1.9.1-taction2

  • Improved internal error handling
  • Released 20.12.2011

Version 1.9.1-taction1

  • Bug fixes
  • TUIO support
  • UI updates
  • Released 19.12.2011